High heat density
Supports processors and racks with concentrated thermal loads.
High-density thermal management
Cold plates, coolant distribution units, immersion systems and heat exchangers for racks where air cooling alone is no longer sufficient.

Technology for critical infrastructure
High-power processors create concentrated heat loads that can exceed the practical limits of conventional airflow. Liquid cooling transfers heat through cold plates or immersion fluids to a controlled facility loop.
A complete design includes the IT loop, CDU, water quality, pumps, redundancy, leak detection, heat rejection and the remaining air-cooling load.
Supports processors and racks with concentrated thermal loads.
Liquid carries more heat with less volume than air.
A CDU separates and regulates facility and technology loops.
Flow, temperature, pressure, leakage and alarms are supervised.
Solution families
The final configuration is confirmed after reviewing capacity, installation conditions, required availability and future expansion.

Direct-to-chip
Cooling plates remove heat directly from processors and other high-power components while the rest of the rack may remain air cooled.

Coolant distribution
Coolant distribution units control temperature, pressure and flow while separating the technology loop from facility water.

Immersion cooling
IT equipment is immersed in a dielectric fluid, providing direct heat transfer for very high-density applications.

Hybrid heat rejection
Liquid-cooled racks still require coordinated room cooling, heat rejection and environmental control for residual loads.
Applications
Equipment selection should reflect the consequences of downtime, site conditions, service strategy and the expected development of the IT load.
Describe your project →GPU clusters with concentrated rack power.
Compute-intensive scientific and engineering systems.
Racks beyond conventional airflow capability.
Compact high-performance systems where space is limited.
Selection criteria
Processor requirements, supported cold plates or immersion compatibility.
Rack power, liquid-cooled share and remaining air-cooling load.
Supply temperatures, water quality, pressure and heat-rejection system.
Pump redundancy, leak detection, controls, maintenance and emergency procedures.
Technical documentation
The 2027 brochures extend the existing documentation with complete CDU systems, immersion cooling, fluid distribution, RDHx and outdoor heat-rejection products.
Frequently asked questions
Not always. Many direct-to-chip systems are hybrid and retain air cooling for components not connected to the liquid loop.
It transfers heat and controls flow, temperature and pressure between the technology and facility loops.
The heat-rejection source depends on the design and operating temperatures; chilled water is one possible option.
The design should include suitable connectors, monitoring, leak detection, isolation and operating procedures.
When processor or rack density approaches airflow limits, or when energy and heat-reuse objectives justify it.
Request a consultation
Send the available project data. We will identify the information required to prepare an appropriate configuration.