High-density thermal management

Liquid cooling for AI and HPC infrastructure.

Cold plates, coolant distribution units, immersion systems and heat exchangers for racks where air cooling alone is no longer sufficient.

  • AI / HPChigh-density computing
  • CDUcontrolled liquid loop
  • Hybridair and liquid architectures
Coolnet liquid-cooling system with a coolant distribution unit and manifold
Coolnet solutionLiquid Coolingselection and integration

Technology for critical infrastructure

Move heat with liquid close to the source.

High-power processors create concentrated heat loads that can exceed the practical limits of conventional airflow. Liquid cooling transfers heat through cold plates or immersion fluids to a controlled facility loop.

A complete design includes the IT loop, CDU, water quality, pumps, redundancy, leak detection, heat rejection and the remaining air-cooling load.

01

High heat density

Supports processors and racks with concentrated thermal loads.

02

Efficient heat transport

Liquid carries more heat with less volume than air.

03

Controlled separation

A CDU separates and regulates facility and technology loops.

04

System monitoring

Flow, temperature, pressure, leakage and alarms are supervised.

Solution families

Select the architecture for the actual application.

The final configuration is confirmed after reviewing capacity, installation conditions, required availability and future expansion.

Coolnet coolant-distribution manifolds for a liquid-cooling system

Direct-to-chip

Cold Plate Cooling

Cooling plates remove heat directly from processors and other high-power components while the rest of the rack may remain air cooled.

  • Targeted processor cooling
  • Hybrid air/liquid operation
  • Rack manifolds and flexible connections
  • Monitoring of flow and temperature
CDU Systems

Coolant distribution

CDU Systems

Coolant distribution units control temperature, pressure and flow while separating the technology loop from facility water.

  • Heat exchanger and pumping module
  • Facility/technology loop separation
  • Redundant pump options by design
  • Controls, alarms and communication
Coolnet Liquid Cooling Tank Cabinet for immersion cooling

Immersion cooling

Immersion Systems

IT equipment is immersed in a dielectric fluid, providing direct heat transfer for very high-density applications.

  • Single- or two-phase concepts depending on project
  • High-density thermal capability
  • Dedicated fluid and tank design
  • Service procedures specific to immersion
Air and Liquid Integration

Hybrid heat rejection

Air and Liquid Integration

Liquid-cooled racks still require coordinated room cooling, heat rejection and environmental control for residual loads.

  • Residual air-load calculation
  • Dry cooler or chilled-water integration
  • Condensation prevention
  • DCIM and facility monitoring

Applications

Infrastructure matched to the operating environment.

Equipment selection should reflect the consequences of downtime, site conditions, service strategy and the expected development of the IT load.

Describe your project
01

AI training

GPU clusters with concentrated rack power.

02

HPC

Compute-intensive scientific and engineering systems.

03

High-density Data Centers

Racks beyond conventional airflow capability.

04

Edge compute

Compact high-performance systems where space is limited.

Selection criteria

What should be confirmed before configuration?

  1. 01

    IT hardware

    Processor requirements, supported cold plates or immersion compatibility.

  2. 02

    Thermal load

    Rack power, liquid-cooled share and remaining air-cooling load.

  3. 03

    Facility water

    Supply temperatures, water quality, pressure and heat-rejection system.

  4. 04

    Reliability

    Pump redundancy, leak detection, controls, maintenance and emergency procedures.

Technical documentation

Coolnet liquid-cooling catalogs.

The 2027 brochures extend the existing documentation with complete CDU systems, immersion cooling, fluid distribution, RDHx and outdoor heat-rejection products.

Explore the complete New Products 2027 portfolio

Frequently asked questions

FAQ: Liquid Cooling

Does liquid cooling replace all air cooling?+

Not always. Many direct-to-chip systems are hybrid and retain air cooling for components not connected to the liquid loop.

What does a CDU do?+

It transfers heat and controls flow, temperature and pressure between the technology and facility loops.

Is chilled water required?+

The heat-rejection source depends on the design and operating temperatures; chilled water is one possible option.

How are leaks managed?+

The design should include suitable connectors, monitoring, leak detection, isolation and operating procedures.

When should liquid cooling be considered?+

When processor or rack density approaches airflow limits, or when energy and heat-reuse objectives justify it.

Request a consultation

Start with IT hardware, rack power and available facility-water conditions.

Send the available project data. We will identify the information required to prepare an appropriate configuration.

The message will be sent directly to Coolnet Poland.